The list below, gives you all of the key NMEA 2000 networking rules that, if followed, will ensure your NMEA 2000 network works correctly.
- The network must be properly terminated; only two terminators fitted one at each end of the backbone
- The NMEA 2000 Supply voltage must be between 9V and 16V
- The NMEA 2000 Supply current must be less than 3A (60 LEN)
- Maximum number of 50 physical devices on the network
- The NMEA 2000 backbone must be less than 100m
- Maximum single drop cable length is 6m
- Total length of all drop cables must be less than 76m
- The volt drop from one end of the network to the other, must be less than 1.5V